ProLink III is a Microsoft Windows-based application for the configuration, service and support of Micro Motion and Rosemount Flow meters.

Using ProLink II Software Figure 3-1 ProLink II main window and Connect dialog box 3.3.1 Connecting to a transmitter Depending on your transmitter, you may have several different options for making the connection from ProLink II to the transmitter. Review the following connection guidelines when selecting your connection method. Instructions for making the connection are provided following the guidelines.

Connection guidelines • You must have the appropriate signal converter for the connection type you choose. See Section 2.2.5. • Modbus connections are faster than HART connections.

• Using a HART connection from ProLink II, you cannot have more than one client window open at a time. • Service port connections - Service port connections are available on all MVD transmitters. - Service ports use standard connection parameters, so you do not have to know the transmitter’s configuration. - ProLink II uses Modbus protocol for service port connections, which is the fastest protocol available. - On Model 1700/2700 transmitters and Model 2400S transmitters, the service port is always available. - On Model 1500/2500 transmitters and Series 3000 transmitters, the service port is available only for ten seconds after power-up.For service port access, you will have to power down the transmitter, which may not be acceptable in your installation. - On Series 1700/2700 transmitters, you must open the wiring compartment to access the service port.

On Model 2400S transmitters, you must remove the housing cover. Therefore, on these transmitters the service port is appropriate only for temporary connections. Using ProLink II Software • HART/Bell 202 connections - HART/Bell 202 connections are available on all transmitters that have an mA output, except the Model 1500 with the Filling and Dosing application. The transmitter Model 1500 with the Filling and Dosing application does not support HART communication.

- HART/Bell 202 connections use standard connection parameters, so you don’t have to know the transmitter’s configuration. - Because the HART/Bell 202 connection is made over the primary mA output terminals, the communication signal can interfere with certain procedures such as loop testing, and may cause the output to change. Depending on how the primary mA output is being used, this may have significant consequences for process control. - Depending on the transmitter and wiring method, HART/Bell 202 connections may be appropriate for both temporary and permanent connections. • RS-485connections - RS-485connections are not available on all transmitters. - To use an RS-485connection, you must know the transmitter’s configuration.

- RS-485connections are appropriate for both temporary and permanent connections. Making the connection 1. Garcea Si Oltenii Download Free.

Ensure that your PC is connected to a transmitter, using one of the methods described in Chapter 2. If the Connect dialog box is not displayed: a.

Open the Connection menu. Freud Instincts And Their Vicissitudes Standard Edition there. Click on the Connect option.

Select the protocol to use. Depending on the Protocol option that you choose, different communications options will be available for configuration. Note: Due to the design of HART protocol, connections made using HART protocol are slower than connections that use Modbus protocol. If you use HART protocol, you cannot open more than one ProLink II window at a time. Note: Windows NT does not support USB connections. Note: If you are using a service port connection to a Model 1500/2500 transmitter or a Series 3000 transmitter, see Section 2.2.6 for instructions on making this connection.

Specify Baud Rate, Parity, Stop Bits, COM Port, and Address/Tag as appropriate for your connection and transmitter. SeeSection 2.2.6 for more information on these parameters. Note: If you are using HART protocol and a HART tag (software tag) has been configured for your transmitter, you can specify the HART tag instead of the HART address. If you are using the Viator USB HART Interface, enable Converter Toggles RTS. Click the Connect button. Note: ProLink II can connect to only one transmitter at a time.

To connect to another transmitter, you must first disconnect from the current connection.

When you need to more fully understand the characteristics of the flow through your meter, the Micro Motion ProLink II ™ transmitter configuration software tool provides a window into your process through the analysis of all flow, density, and temperature parameters. Using HART ® or Modbus ® communication protocols, ProLink II software provides easy-to-use menus, charting, graphing, and evaluation of transmitter alarm conditions that allow you to have your flowmeter up and running quickly, no matter how complex your configuration needs. Please note that ProLink II has been discontinued and we will only be issuing new licenses through May 2015.